1-way Cassette Type
Product Advantages
- 360° Air Supply Louvers are consist of horizontal and vertical flaps to supply air evenly to the edges of any rooms. Wider opening angle from 17° to 65° supplies air further and lower down to floor needed during heating modes.
- Space Saving Slim body height of 192mm fits in limited ceiling spaces commonly seen in budget hotels and residential applications.
- Maintain never been easier The electricity box of the cassette is designed and placed beneath the panel. Service, maintenance and commissioning have never made simpler without crawling into service manholes for simple adjustments on the PCB board.
2-way Cassette Type
Product Advantages
- Compact and Classy Design The slim structure of the cassette having height as low as 298mm can be installed in ceiling spaces with a minimum of 310mm. Narrow corridors or zoned spaces are best fitted with 2 way cassette due to its compact design.
- Individual Louver Control Each louver's opening angles are controllable individually with a total of 8 choices, with opening angle from 27° to 84° to cover high ceiling narrow long corridors needs and effective warm air supply during winter seasons.
- Branch Discharge Option In irregular room layouts, branch discharge could come in handy by extending air distribution area to the most awkward corners without additional indoor units.
4-way Cassette Type
Product Advantages
- Compact and Classy Design The 4 way cassette is now as slim as 238mm and 215mm for mini 4-way cassettes , fit for narrow ceiling spaces. Boring straight return air grille patterns are replaced with exquisite hexagon pattern design, upgrading taste and classiness of any interior aesthetic.
- Independent Louvers Control All 4 louvers on the cassette units can be adjusted independantly in any 8 positions from 0° (closed) to 65° for more precise airflow direction maximizing user's comfort and adapting to various space layouts.
- Motion Sensor The sensor senses the presence of people to automatically turn the cassette unit on or off and whether to direct airflow towards or avoiding humans depend settings set on the controller. During crowded times, the setting temperature is automatically lowered down and vise versa. Meeting comfort and using energy only when necessary.
Air Cooled Screw
• Inverter air cooled screw chiller
• Capacity from 556 to 1330 KW
Brushless Direct Current (BLDC) FCU
KINGAIR fan coil unit applied the latest technology of permanent magnet brush less direct current motor which can proceed continuous and steeples capacity control. Power consumption at low speed operation is 75% lower than National Standard. Low noise, high efficiency, energy saving with isothermal control, it is your best choice of highly energy saving Fan Coil Unit.
Ceiling and Floor Type
Product Advantages
- Sleek Smooth Design Shiny white cover panel of the unit has an streamlined elegant aesthetic. The bolts and nuts used to secure the unit onto wall or ceiling are designed to be concealed in the unit for a sleek room interior look.
- Flexible Installation The unit can be installed to be standing on floors or hanging on ceilings. Whereby interior walls maximized to display items, can hang the unit on the ceiling.
- 3D Air Supply Louvers are consist of horizontal and vertical flaps to cover larger coverage area to the edges of any rooms. Wider opening angle from up to 120° for vertical louvers and up to 71° for horizontal louvers supply air further and lower down to floor needed during heating modes.
- Convenient Installation and Maintenance Adjust the ceiling or wall mounting height by just opening the side panels without the need to access the internal parts. Service manholes are unnecessary due to the strategic repositioning of piping connections and electrical box behind the air return panel, service and clean the filter all in the same compartment.
Ceiling Ducted Type (AC Low-Height)
Product Advantages
- Space Saving Concealed AC/DC Low Height Ducted unit is as slim as 192mm, fitting into the narrowest ceiling spaces. Save ceiling spaces for higher room height without compromising user's comfort and satisfaction.
- Adjustable Static Pressure* Static pressures in free supply applications would create unnecessary air-blowing noises. Hence, the fan's static pressure is made adjustable to suit different applications more precisely with smaller adjustment steps.*: AC/DC Low Height,Low Static and High Static Pressure Ducted Unit have different number of static pressure choices, please refer to the specifications for more detail information.
- Various Device Connection Options Third party devices and sensors to control the power supply are possible with dry contact connections to the indoor unit.Devices like hotel room key card, window contact and fire alarms can be connected simultaneously.
Ceiling Ducted Type (DC Low-Height)
Product Advantages
- Window Contact Design The operation conditiion of the unit links with the window status through the window sensor and the Hisense indoor unit input function. This function saves energy and the automatic switch setting procides convenience for users.
- More Choice of the Optional Module The unit can be controlled automatically through the Hi-Motion. Humidity Sensor achieves the automatic dehumidification. 3D air flow provides more comfortable air supply mode.
- Adjustable Indoor Unit Static Pressure Indoor unit can adjust static pressure automatically according to the house structure and installation condition, ensure that the indoor unit operates in the optimum exhaust state.
- Optimized Design of the Duct The unit optimizes the duct structure and gets the patent (NO.HX20163504), which improves the ventilation of the heat exchanger near the drain pan. The noise level is reduced and the efficiency of the heat transfer is enhanced.
- Drain Pump as Standard Part Drain-up length achieves 900mm which enables convenient drain piping and enlarges the flexibility of installation.
Ceiling Ducted Type (Low/High-Static Pressure)
Product Advantages
- Installation Space-Saving Less than 270mm in height can be easily fit into the limited space in the false ceiling (7.5-24.2KBtu/h).
- Flexibly Supports a Wide Range of Installation
- Fresh Indoor Air
- Excellent Air Flow
- Optional Parts Drain pump can be supplied as optional part
Centrifugal Chiller
• Inverter direct-drive full falling film centrifugal chiller
• Magnetic full falling film centrifugal chiller
• High-efficiency water cooled centrifugal chiller
• Super high efficiency water cooled centrifugal chiller
Chilled Water Low Static Ducted Units (SCLF Series)
• Capacity range: 200 ~ 2000 CFM.
• Wide external static pressure supplying. Three external static pressure(12Pa/30Pa/50Pa) settings for added flexibility.
• Standard extended drainage pan for protecting your ceiling better.
• Left or right hand piping connections, field convertible.
• Flexible control, remote controller and wired controller are optional.
• A patent design is able to prevent abnormal noise caused by blowing fins.
• Higher efficient heat exchange for complete contranatant flow.
• Return air plenum and filter are standard.
• Fresh air supply makes life healthier and more comfortable.
• 220-240V/1Ph/50Hz power supply is standard.